HI, I’m seeing the below errors on a IRF stack of 5900AF switches
The switch is rack ports front power supply rear.
The DC advise that the power supplys suck are in (wrong direction) but the fans blow out the back.
[Master01]dis log | inc Oct
%Oct 20 03:40:37:565 2014 Master01 SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=192.168.3.10-User=admin; Command is display ntp-service status
%Oct 20 03:40:55:142 2014 Master01 DEV/1/FAN_DIRECTION_NOT_PREFERRED: -Slot=2; Fan 1 airflow direction is not preferred on slot 2, please check it.
%Oct 20 03:40:55:144 2014 Master01 DEV/1/FAN_DIRECTION_NOT_PREFERRED: -Slot=2; Fan 2 airflow direction is not preferred on slot 2, please check it.
%Oct 20 03:40:58:357 2014 Master01 SHELL/6/SHELL_CMD: -Line=vty0-IPAddr=192.168.3.10-User=admin; Command is dis log
%Oct 20 03:41:16:853 2014 Master01 DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 1 airflow direction is not preferred on slot 1, please check it.
%Oct 20 03:41:16:853 2014 Master01 DEV/1/FAN_DIRECTION_NOT_PREFERRED: Fan 2 airflow direction is not preferred on slot 1, please check it.
[Master01]dis device manuinfo
Slot 1
DEVICE_NAME : 5900AF-48XG-4QSFP+ JC772A
DEVICE_SERIAL_NUMBER : XXXXXXXXX
MAC_ADDRESS : 4431-922B-88B3
MANUFACTURING_DATE : 2013-11-20
VENDOR_NAME : HP
Fan 1
DEVICE_NAME : HP A58x0AF frt(ports)-bck(pwr) Fan Tray JC683A
DEVICE_SERIAL_NUMBER : CN47FDF1WG
MANUFACTURING_DATE : 2014-07-19
VENDOR_NAME : HP
Fan 2
DEVICE_NAME : HP A58x0AF frt(ports)-bck(pwr) Fan Tray JC683A
DEVICE_SERIAL_NUMBER : CN47FDF1T6
MANUFACTURING_DATE : 2014-07-19
VENDOR_NAME : HP
[Master01]dis environment Slot 1 System temperature information (degree centigrade): ------------------------------------------------------------------------------- Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit hotspot 1 40 0 50 55 NA hotspot 2 38 0 58 63 NA Slot 2 System temperature information (degree centigrade): -------------------------------------------------- ----------------------------- Sensor Temperature LowerLimit WarningLimit AlarmLimit ShutdownLimit hotspot 1 41 0 50 55 NA hotspot 2 40 0 58 63 NA [Master01]dis fan Slot 1 FAN 1 State : FanDirectionFault Wind Direction :Port-to-Power Prefer Wind Direction :Power-to-Port FAN 2 State : FanDirectionFault Wind Direction :Port-to-Power Prefer Wind Direction :Power-to-Port Slot 2 FAN 1 State : FanDirectionFault Wind Direction :Port-to-Power Prefer Wind Direction :Power-to-Port FAN 2 State : FanDirectionFault Wind Direction :Port-to-Power Prefer Wind Direction :Power-to-Port The Fix :
Turned out to just be a preferred setting.
[Master01]fan prefer-direction slot 1 port-to-power
[Master01]fan prefer-direction slot 2 port-to-power
[Master01]dis log | inc recovered
%Oct 20 06:00:45:653 2014 Master01 DEV/5/FAN_RECOVERED: Fan 1 recovered.
%Oct 20 06:00:45:655 2014 Master01 DEV/5/FAN_RECOVERED: Fan 2 recovered.
%Oct 20 06:01:00:791 2014 Master01 DEV/5/FAN_RECOVERED: -Slot=2; Fan 1 recovered.
%Oct 20 06:01:00:793 2014 Master01 DEV/5/FAN_RECOVERED: -Slot=2; Fan 2 recovered.
[Master01]dis fan
Slot 1
FAN 1
State : Normal
Wind Direction :Port-to-Power
Prefer Wind Direction :Port-to-Power
FAN 2
State : Normal
Wind Direction :Port-to-Power
Prefer Wind Direction :Port-to-Power
Slot 2
FAN 1
State : Normal
Wind Direction :Port-to-Power
Prefer Wind Direction :Port-to-Power
FAN 2
State : Normal
Wind Direction :Port-to-Power
Prefer Wind Direction :Port-to-Power